VTC605 Series Step-Up Converters

Benefits
- Ultra-Quiet
- Power sensitive electronics without interference
- Rugged & Reliable
- Ensure years of safe and trouble free operation
- Download Data Sheet
Step up a 12 VDC battery to between 13.5 and 17.0 or 24.0 and 27.5 VDC in 0.5 VDC increments (via 3 position DIP switch), or stabilize a 12 or 24 VDC power system.
Safety features include reverse input protection, low input voltage alarm, low output voltage alarm, over temperature shutdown and alarm, a dry contact alarm relay output and output overvoltage crowbar. If the input voltage exceeds the regulated output voltage, the unit simply passes the voltage through with full LC filtering and a single schottky diode drop (0.5 VDC or less). Optional features include remote panel monitoring with On/Off control.
Applications include temporarily brightening 12 volt headlights or work lights, increasing voltage into an automotive or marine ignition system for hotter spark and/or prevention of failures due to voltage drop during engine start, stabilizing 12V and 24 VDC power systems in marine, automotive or aeronautical environments and more.
Features
- Vibration proof output voltage adjustment by 3 position DIP switch
- Audible & visual indicators for constant current, low input voltage, low output voltage & over-temperature
- Extremely rugged and well suited for marine and other demanding environments
- High tolerance for shock and vibration
- Ultra-quiet low EMI operation
- Current limiting protection
- Reverse input protection
- Output over-voltage crowbar
- Dry contact output fail relay
- Remote control option
- Wide-Temperature operation Available
- Parallel output diodes available
- Conformal Coating and/or Harsh Environment Ruggedization Available
- 3 year parts and labour warranty
Applications
- Marine & other rugged environments
- Mobile Offices (TV and Radio Vans)
- Automotive / RV
- Electric Utilities and Substations
- Base Station Power(Radio & Telecommunications)
- Industrial Controls(OEM Applications)
- Field Work / Construction Sites
- Solar/Alternative Power Systems
- Any 12 or 24V Equipment
| Input Volts(DC) | 10.5-18 | 10.5-28 |
|---|---|---|
| Input Amps (Max) | 50 | |
| Input Fuse (AGC) | 25x 2 Amp | |
| Noise on Input | < 50 mV | |
| Low Input Voltage Alarm |
10.5 VDC | |
| Current Limit | 50 Amps in | |
| Output Nominal (op) | 12 | 24 |
|---|---|---|
| Output Volts (DC) | Input - 1V or 13.5 to 17.0 Whichever is greater |
Input - 1V or 24.0 to 27.5 Whichever is greater |
| Output Adjustment | * 45 | |
| Output Crowbar | Programmed Output Volts x (1.3 ± 1%) | |
| Output Ripple & Noise | < 50 mV | |
| Low Output Voltage Alarm |
Programmed Output Voltage minus 2.5 VDC |
|
| Transient Response | < 1V for 50% Surge | |
| Regulation (Line & Load) |
< +/- 0.5% | |
| Duty Cycle | Continuous 100% for 24 hours per day | |
| Efficiency | > 90% @ Maximum Output | |
To obtain the actual output current capability at any given input voltage,
use the following formula:
Output Amps = Input Volts/Output Volts x 45
For example, at 10.5 VDC in and 13.6 VDC out, the output current = 10.5/13.6 x 45 = 34.7 amps
| Operating Temp. Range | -25° to +40°C @ maximum output Derate Linearly 2.5% per°C from 40°C (Optional -40°C extra wide temp. operation avail.) |
|---|---|
| Humidity | 0 - 95°C Relative Humidity (non-condensing) with optional conformal coating |
| Audible Noise | NONE Ødb @ 3 ft |
| Typical Service Life | >10 years (87,600 hours) |
| Isolation | Any Input or Output to Case 500 VDC Input to Output – Common Negative |
| Length | 9.1 in/ 23.1 cm |
|---|---|
| Width | 7.8 in/ 19.8 cm |
| Height | 4.3 in/ 10.8 cm |
| Material | Marine Grade Aluminium |
| Finish | Black Anodize / Powder Epoxy Coat |
| Fastenings | All 18-8 Stainless Steel |
| Weight | 6.0 lb / 2.7 kg |
| Connections | Four contact output terminals |
| Warranty | 3 years |
Toll Free: 1-800-668-3884
Tel: 604.946.9981
Fax: 604.946.9983
Email Us
Facebook/Twitter/LinkedIn: