This all new single board design incorporates state of the art switchmode technology for unmatched efficiency and ultra-quiet operation.


Multiple stages of filtering reduce radiated or conducted noise to very low levels. Extra features include adjustable output voltage, audible and visual indicators for low input voltage, low output voltage, over temperature and overload.


Safety features include reverse input protection, over-temperature shutdown, current limiting, short circuit shutdown, a dry contact alarm relay output and output overvoltage crowbar. Optional features include a remote panel monitoring with On-Off control.


We are confident that you will get many years of reliable service from this Voltage Converter.


Features

  • Adjustable output voltage
  • Audible & visual indicators for constant current, low input voltage, low output voltage & over-temperature
  • Extremely rugged and well suited for marine and other demanding environments
  • High tolerance for shock and vibration
  • Ultra-quiet low EMI operation
  • Current limiting protection
  • Reverse input protection
  • Output over-voltage crowbar
  • Dry contact output fail relay
  • Remote control option
  • Wide-Temperature operation Available
  • Parallel output diodes available
  • Conformal Coating and/or Harsh Environment Ruggedization Available
  • 3 year parts and labour warranty

Applications

  • Marine & other rugged environments
  • Mobile Offices (TV and Radio Vans)
  • Automotive / RV
  • Electric Utilities and Substations
  • Base Station Power(Radio & Telecommunications)
  • Industrial Controls(OEM Applications)
  • Field Work / Construction Sites
  • Solar/Alternative Power Systems
  • Emergency Backup Power (UPS)

Electrical [Input]
Model Number VTC300-32-12 VTC300-32-24
Input Volts(DC) 20-45 30-45
Input Amps (Max) 20 22
Input Fuse (AGC) 25A
Noise on Input < 25mV
Electrical [Output]
Output Nominal (op) 12 24
Output Volts (DC) 13.6 ± 0.05 27.2 ± 0.05
Output Adjustment ± 0.05  
Output Current(Amps) 25 cont./ 35 peak 20 cont./ 25 peak
Current Limit 37 Amps 27 Amps
Output Crowbar 16.0 ± 0.5V 32.0 ± 1.0V
Output Ripple & Noise < 25 mV
Transient Response < 1V for 50% Surge
Regulation
(Line & Load)
< +/- 0.5%
Duty Cycle Peak 20% for 10 min maximum
Continuous 100% for 24 hours per day
Efficiency > 90% @ Maximum Output
Environmental Specification
Operating Temp. Range -25° to +40°C @ maximum output
Derate Linearly 2.5% per°C from 40°C
(Optional -40°C extra wide temp. operation avail.)
Humidity 0 - 95°C Relative Humidity
(non-condensing) with optional conformal coating
Audible Noise NONE Ødb @ 3 ft
Typical Service Life >10 years (87,600 hours)
Isolation Any Input or Output to Case 500 VDC
Input to Output – Common Negative
Mechanical Specification
Length 9.1 in/ 23.1 cm
Width 7.8 in/ 19.8 cm
Height 2.5 in/ 6.4 cm
Material Marine Grade Aluminium
Finish Black Anodize / Powder Epoxy Coat
Fastenings All 18-8 Stainless Steel
Weight 4.0 lb / 1.8 kg
Connections #12 AWG Input Wires (Positive & Negative)
Four contact output terminal
Warranty 3 years
VTC300 mechanical drawing
 
Product Catalogue
Analytic Systems Impact Movie

Feb 2, 2012 - Analytic Systems Provides Power for US Army Tactical Comms » PDF icon

Jan 16, 2012 - Analytic Systems Certified to AS9100 » PDF icon

Oct 11, 2011 - Analytic Systems Commercial Marine Products ABS Certified » PDF icon

Toll Free: 1-800-668-3884
Tel: 604.946.9981
Fax: 604.946.9983
Email Us
Facebook/Twitter/LinkedIn:
linkedin