The VTC1503 Series of voltage converters provides 12, 24 or 48 Volts DC at 25 to 100 Amps of continuous power from a 72, 110 or 250 Volt DC source.


Analytic Systems' Voltage Converters use Switchmode technology with powerful IGBT switching transistors for reliability and efficiency with minimum size. Circuit innovations reduce output ripple to levels previously available only from bulky and inefficient linear power supplies. Reliability features include an input fuse, thermal shutdown, current limiting and output short circuit protection with automatic recovery. An Output Over voltage Crowbar circuit protects any powered devices from excessive voltage in the event of a failure of the unit.


The newly updated single-board VTC1503 is ultra-quiet and features the latest generation of current mode PWM control. Extra features include audible and visual indicators for over temperature and output on.


Features

  • Military-Grade extrusion ensures a high tolerance for shock and vibration
  • Can be left permanently connected
  • 3 Bank Load Splitter Available
  • Over-temperature shutdown
  • Short circuit protection
  • Visual indicators for output voltage & over-temperature
  • Output over-voltage crowbar
  • Inrush Current Limiting with solid state bypass
  • Thermostatically controlled fan
  • 3 year parts and labour warranty

Applications

  • Marine & other rugged environments
  • Automotive / RV
  • Electric Utilities and Substations
  • Base Station Power Radio & Telecommunications)
  • OEM Applications
  • Field Work / Construction Sites
  • Solar Power Systems
  • Emergency Power Backup (UPS)
  • Security Systems
  • Power any 12, 24 or 48 Volt Electronic Equipment

Electrical [Input]
Nominal Vac (ip) 110 250 300 360
Actual (Vdc) 100-140 230-280 280-360 330-415
Input Amps (Max) 21 9 7.5 6.5
Input Fuse (MDA) 25 15 10 8
Noise on Input < 50mV
Electrical [Output]
Output Nominal (op) 12 24 32 48
Output Volts (VDC) 13.6 ± 0.05 27.2 ± 0.05 36.6± 0.05 54.4 ± 0.05
Output Amps 100A 50A 35.5A 25A
Output Crowbar 16.0 ± 0.5V 32.0 ± 1.0V 43.7 ± 1.0V 63.9 ± 2.0V
Output Ripple & Noise < 50 mV
Regulation
(Line & Load)
< +/- 0.5%
Duty Cycle Continuous 100% for 24 hours per day
Efficiency > 80% @ Maximum Output
Environmental Specification
Operating Temp. Range -25° to +40°C @ maximum output
Derate Linearly 2.5% per°C from 40°C
(Optional -40°C extra wide temp. operation avail.)
Humidity 0 - 95°C Relative Humidity
(non-condensing) with optional conformal coating
Audible Noise NONE Ødb @ 3 ft (34.5 dB when fan operating)
Typical Service Life >10 years (87,600 hours)
Isolation Input-Case & Input-Output 1500VDC/ Output-Case 500VDC
Mechanical Specification
Length 17.0 in/ 43.2 cm
Width 8.2 in/ 20.8 cm
Height 3.5 in/ 8.9 cm (Without carring handle)
Clearance 1 inch (2.5 cm) all around
Material Marine Grade Aluminium
Finish Black Anodize
Fastenings All 18-8 Stainless Steel
Weight 14.4 lb / 6.6 kg
Connections 4ft #6awg input, blk/red #6awg output wires
Warranty 3 years
VTC1503 mechanical drawing
 
Product Catalogue
Analytic Systems Impact Movie

Apr 13, 2012 - Anniston Army Depot Contracy Award to Analytic Systems » PDF icon

Feb 2, 2011 - Analytic Systems Celebrates "Best In Class" Quality Rating from SRC Tec » PDF icon

Feb 2, 2012 - Analytic Systems Provides Power for US Army Tactical Comms » PDF icon

Toll Free: 1-800-668-3884
Tel: 604.946.9981
Fax: 604.946.9983
Email Us
Facebook/Twitter/LinkedIn:
linkedin