BCD60 Battery Charger

Benefits
- Ultra-Quiet
- Power sensitive electronics without interference
- Rugged & Reliable
- Ensure years of safe and trouble free operation
- Fast & Accurate Charging
The BCD60-24-12 Voltage Converter supplies 12 Volts DC from a 24 VDC Battery System at up to 7 amps. The BCD60-12-5 supplies 5 Volts from a 12 VDC battery system.
Designed for use in heavy equipment, marine, industrial, or alternative energy environments, the state-of-the-art switchmode design offers high reliability and efficiency in a very small package. They are rugged, easy to use and very economical.
An optional remote on/off feature is available to allow the supply to be turned on or off from a remote location or in sync with other controls.
Features
- Input voltage range allows operation from 12, 24, 32, or 48 volt batteries
- Reverse input protection
- Extremely rugged and well suited for marine and other demanding environments
- High tolerance for shock and vibration
- Short circuit protection /li>
- Output over-voltage crowbar
- Inrush current limiting
- Wide operating temperature range
- Remote On-Off version available
- Wide-Temperature Operation Available
- Potting to Class 1, Div 2 Standards Available
- Conformal Coating and/or Harsh Environment Ruggedization Available
- 3 year parts and labour warranty
Applications
- Oil Patch
- Mobile Offices (TV and Radio Vans)
- Marine / Automotive / RV
- Industrial Controls (OEM Applications)
- Computer Systems
- Field Work / Construction Sites
- Solar / Alternative Power Systems
- Run any 5V or 12V Equipment
| Input Volts (ip) | 10.5 – 16.0 | 20 – 35 |
|---|---|---|
| Input Amps (Max) | 3.7 | 5.4 |
| Input Fuse (MDA) | 5 | 10 |
| Noise on Input | < 10mV | |
| Output Nominal (op) | 5 | 12 | ||
|---|---|---|---|---|
| Output Volts (DC) | 5.0 | 13.6 | ||
| Output Amps | 5 cont. / 7 peak | |||
| Output Crowbar | 7.0 ± 0.5V | 16.0 ± 0.5V | ||
| Output Ripple & Noise | < 10mV | |||
| Transient Response | < 1.0V for 50% surge | |||
| Regulation (Line & Load) | < ± 0.5% | |||
| Duty Cycle | Peak 20% for 10 min maximum Continuous 100% for 24 hours per day |
|||
| Efficiency | > 88% @ Maximum Output | |||
| Operating Temp. Range | -25° to +40°C @ maximum output Derate Linearly 2.5% per °C from 40°C (Optional -40°C extra wide temp. operation avail.) |
|---|---|
| Humidity | 0 - 95°C Relative Humidity (non-condensing) with optional conformal coating |
| Audible Noise | NONE Ødb @ 3 ft |
| Typical Service Life | >10 years (87,600 hours) |
| Isolation | Any Input or Output to Case 500 VDC Input to Output - Common Negative |
| Length | 5.5 in / 14.0 cm |
|---|---|
| Width | 4.0 in / 10.2 cm |
| Height | 2.1 in / 5.3 cm |
| Material | Marine Grade Aluminium |
| Finish | Black Anodize / Powder Epoxy Coat |
| Fastenings | All 18-8 Stainless Steel |
| Weight | 0.8 lb / 0.4 kg |
| Connections | Four contact output terminals |
| Warranty | 3 years |
Toll Free: 1-800-668-3884
Tel: 604.946.9981
Fax: 604.946.9983
Email Us