AC Inverters
Analytic Systems produces three types of inverters converting DC to AC – our IQS, IPS and IVS PureSine Series. Run 120 or 220 volt Ac equipment trouble free from 12, 24, 32, 36, 48 or 72V DC batteries in any environment where standard AC power is not available. Powerful MosFet transistors, coupled with Analytic Systems’ sensitive control circuitry provide reliable operation in the most demanding environments. The ON-OFF switch illuminates when AC power is present, providing positive indication of proper operation. Heavy input filtering ensures that no electrical noise will be generated to interfere with autopilots, radios, or other devices sharing the same batteries. The transformer-type output provides protection against the generation of electrical ‘noise’ and gives excellent filtering of the AC waveform to ensure trouble-free operation of any type of AC equipment. The power our IPS and IVS Series Inverters produce is cleaners and has less fluctuation than even household AC.
Toll Free: 1-800-668-3884
Tel: 604.946.9981
Fax: 604.946.9983
Email Us
Facebook/Twitter/LinkedIn:
| IPS600 | Input Voltage (VDC) |
Output Voltage (VAC) |
Output Amps (Cont.) |
Part Number | Data Sheets |
|---|---|---|---|---|---|
![]() |
10.5-16V | 115+/-5.0V | 5.0 cont. | IPS600-12-110 |
![]()
|
| 20-40V | 3.2 cont. | IPS600-20-220 | |||
| IPS2000 | Input Voltage (VDC) |
Output Voltage (VAC) |
Output Amps (Cont.) |
Part Number | Data Sheets |
|---|---|---|---|---|---|
![]() |
20-40V | 115+/-5.0V | 17.4 cont. | IPS2000-24-110 |
![]()
|
| 220+/-10.0V | 8.7 cont. | IPS2000-24-220 | |||
| Optional Features (IPS and IQS Models) | |
|---|---|
| RCP1-IPS | Remote Control Panel (IPS) |
| RCP1-IQS | Remote Control Panel (IQS) |
| LINE AC | Line AC Detect & Autoswitch (UPS Option for IPS600-1500) |
| GFI | Ground Fault Interrupt Receptacle |
| HANDLE | Handle for IPS300 |
| FL | Forklift Modification (Required for Electric Forklifts) |
| IVS100 | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,32,48,125 | 100 | 115 | 0.87 |
![]()
|
| IVS200 | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,36,48,125 | 200 | 115/230 | 1.7/ 0.86 |
![]()
|
| IVS300 | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,32,48,125 | 300 | 115/230 | 2.6/ 1.3 |
![]()
|
| IVS500 | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,32,48, 72,125,250 |
500 | 115/230 | 4.4/2.17 |
![]()
|
| RVS500 | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
125 | 500 | 115/230 | 4.4/ 2.2 |
![]()
|
| IVS1000 | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,32,48,125,250 | 1000 | 115/230 | 8.7/ 4.34 |
![]()
|
| LVS1000 | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,36,125,250 | 1000 | 115/230 | 8.7/ 4.34 |
![]()
|
| RVS1000 | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,36,48,125,250 | 1000 | 115/230 | 8.7/4.34 |
![]()
|
| IVS1500 | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,32,48,72,125,250 | 1500 | 115/230 | 13.0 |
![]()
|
| IVS2000 | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,32,48,72 125,250 |
2000 | 115/230 | 17.4 |
![]()
|
| Optional Features (IVS and Rackmount Models) | |
|---|---|
| RACK | Custom 4U - 19" Rackmount w/ Handles (IVS250-2000) |
| SSC1000 | Soft Start Cicuit for Motors (up to 1000W) |
| ACF2624- ALARM | Inverter Fail Alarm, Form C Contact |
| 400Hz | Custom 400Hz Frequency Available |
| RUGGED | Ruggedizing |
| CONFORM | Conformal Coating |
| LOW TEMP. | LowTemperature (-35 degree operation) |
| CUSTOM | Input/Output Voltages (Available Upon Request) |
| IVS2000R | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,36,48,125,250 | 2000 | 115/230 | 17.4/8.7 |
![]()
|
| IVS2500R | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,36,48,125,250 | 2500 | 115/230 | 21.7/10.9 |
![]()
|
| IVS3000R | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,36,48,125,250 | 3000 | 115/230 | 26.0 |
![]()
|
| IVS4000R | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,36,48,125,250 | 4000 | 115/230 | 34.0 |
![]()
|
| IVS5000R | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,36,48,125,250 | 5000 | 115/230 | 43.5 |
![]()
|
| ITS5000R | Standard Input Voltage (VDC) |
Output Power (VA) |
Output Voltage (VAC) |
Output Current (Amps) |
Data Sheets |
|---|---|---|---|---|---|
![]() |
24,36,48,125,250 | 5000 | 115/230 | 43.5 |
![]()
|
| Optional Features (IVS and Rackmount Models) | |
|---|---|
| RACK | Custom 4U - 19" Rackmount w/ Handles (IVS250-2000) |
| SSC1000 | Soft Start Cicuit for Motors (up to 1000W) |
| ACF2624- ALARM | Inverter Fail Alarm, Form C Contact |
| 400Hz | Custom 400Hz Frequency Available |
| RUGGED | Ruggedizing |
| CONFORM | Conformal Coating |
| LOW TEMP. | LowTemperature (-35 degree operation) |
| CUSTOM | Input/Output Voltages (Available Upon Request) |